AP 880

PRODOTTI : PERKINS Alternatore: ECO 43-1S/4 A Sistema Controllo: DSE 7320
introduzione
Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.
Caratteristiche Generali
Nome del Modello AP 880
Frequenza (Hz) 50
Tipo di carburante Diesel
Motore Made e Modello PERKINS - 4006-23TAG3A
Il Modello Mecc Alte - ECO 43-1S/4 A
Sistema Controllo DSE 7320
Cabina AK 91
3 Fase, 50 Hz, PF 0.8
Tensione (AC) Potenza Standby (ESP) Potenza Primaria (PRP) Standby Amper
kVA kW kVA kW
400/231 880 704.0 800 640.0 1270.21
Potenza Standby (ESP) : In caso di interruzione delle risorse di rete affidabile, viene utilizzato per alimentare il carico elettrico alternativo. ESP, è compatibile con ISO8528. Non è consentito per sovraccarico.

Potenza Primaria (PRP) : Viene utilizzato per ore illimitate annuale, per alimentare il carico elettrico alternativo. PRP, è compatibile con ISO 8525. Secondo la norma ISO 3046, nel periodo di lavoro di 12 ore, viene utilizzato per il sovraccarico di 10% per un ora.
Specifiche del Motore
Motore PERKINS
Modello del motore 4006-23TAG3A
Numero e Dispozione Cilindri 6 cylinders - in line
Alesaggio x Corsa mm 160 X 190
Cilindrata L 22.921
Aspirazione Turbo Charged
Rapporto Compressione 13.6:1
Velocità nominale (rpm) d/dk 1500
Capacità olio (lt) L 113.4
Potenza Standby (kW/HP) 786/1053,61
Prime Potenza (kW/HP) 705/945,03
Block Heater QTY
1
Block Heater Power (Watt)
4000
Tipo di carburante
Diesel
Injection Type and System
Direct
Type of Fuel Pump
Mechanical
Governor System
Electronic
Tensione di funzionamento (Vdc)
24 Vdc
Battery and Capacity (Qty/Ah)
2x143
Charge Alternator (A)
55
Cooling Method
Water Cooled
Cooling Fan Air Flow (m3/min)
870
Filtro dell'aria
Dry Type
Fuel Cons. Prime With %100 Load (lt/hr)
172
Fuel Cons. Prime With %75 Load (lt/hr)
130
Fuel Cons. Prime With %50 Load (lt/hr)
90
Specifiche del Motore
Manufacturer Mecc Alte
Il Modello ECO 43-1S/4 A
Frequenza (Hz) Hz 50
energia (kVA) kVA 820
Design   4 Pole,  Brushless
Tensione (AC) V 400
Fase 3
Il Regolatore Automatico di Tensione DER1
La Regolazione della Tensione (+/-) 0.5
isolamento sistema H
Protezione IP23
Fattore di potenza 0.8
Il Peso Completo del Generatore (Kg) 1920
L'Aria di Raffreddamento m3 90
Dimensioni e peso
Tipo aperto Peso a secco (Kg)
(kg.)
Lunghezza (mm)
(mm.)
Larghezza (mm)
(mm.)
Altezza (mm)
(mm.)
Capacità Serbatoio (L) (Lt.)
5500 4100 1705 2270 1500
Cabina Peso a secco (Kg)
(kg.)
Lunghezza (mm)
(mm.)
Larghezza (mm)
(mm.)
Altezza (mm)
(mm.)
Capacità Serbatoio (L) (Lt.)
AK 91
7500 5920 2286 2340 1100
Specifiche Standard

- Water cooled, Diesel engine

- Radiator with mechanical fan

- Protective grille for rotating and hot parts

- Electric starter and charge alternator

- Starting battery (with lead acid) including rack and cables

- Engine coolant heater

- Steel base frame and anti-vibration isolators

- Spare external fuel tank

- Flexible fuel connection hoses

- Single bearing, class H alternator

- Industrial exhaust silencer and steel bellows supplied separately(for open sets)

- Static battery charger

- Manual for application and installation

Apparecchiature Opzionali
ENGINE
• Fuel-Water Seperator Filter
• Low water level alarm
• Oil heater

ALTERNATOR
• Anti-Condensation Heater
• Over sized alternator
• Single Phase ( 4 lead)
• Main line circuit breaker

CONTROL SYSTEM
• Remote annunciator panel
• Earth fault, single set
• Charge Ammeter

TRANSFER SWITCH
• Three or four pole contactor
• Three or four pole motor operated circuit breaker

OTHER ACCESSORIES
• Main Fuel Tank
• Automatic or manual fuel filling system
• Manual oil drain pump
• Low and high fuel level alarm
• Residential silencer
• Enclosure: weater protective or sound attenuated
• Duct adapter ( on radiator)
• Inlet and outlet motorised louvers
• Inlet and outlet acoustic baffles
• Trailer
• Tool kit for maintenance
• 1500/3000 hours maintenance kit
• Double wall chassis
• Supplied with oil and coolant - 30 °C
Sistema Controllo: DSE 7320
1. Menu navigation buttons 
2. Close mains button 
3. Main Status and instrumentation display 
4. Alarm LED's 
5. Close generator button 
6. Status LED's 
7. Operation selecting buttons
1. Menu navigation buttons 
2. Close mains button 
3. Main Status and instrumentation display 
4. Alarm LED's 
5. Close generator button 
6. Status LED's 
7. Operation selecting buttons
Dispositivi

DSE model 7320, Auto Mains Failure control module, with a highly sophisticated level of new features and functions

Static battery charger, Fuses for control circuits

COSTRUZIONE E COMPLETAMENTO

- Components installed in sheet steel enclosure.

- Phosphate chemical, pre-coating of steel provides corrosion resistant surface

- Polyester composite powder topcoat forms high gloss and extremely durable finish

- Lockable hinged panel door provides for easy component access

Installazione

The Control panel is mounted at the generating set baseframe on robust steel stand or power module. Located at side

of generating set with properly panel visibility.

UNITÀ DI CONTROLLO GENERATORE

- The DSE 7320 control module is a standard addition to our generator sets from 220 kVA upwards and it has been

designed to start and stop diesel and gas generating sets that include electronic and non electronic engines.

- The DSE 7320 includes the additional capability of being able to monitor a mains (utility) supply and is therefore suitable

for controlling a standby generating set in conjunction with an automatic transfer switch.

- The DSE7320 also indicates operational status and fault conditions, automatically shutting down the generating set and

indicating faults by means of its LCD display on the front panel.


Instruments
ENGINE
Engine speed
Oil pressure
Coolant temperature
Run time Battery volts
Engine maintenance due

GENERATOR
Voltage (L-L, L-N)
Current (L1-L2-L3)
Frequency
Earth current
kW
Pf
kVAr
kWh, kVAh, kVArh
Phase sequence

MAINS
Voltage (L-L, L-N)
Frequency

Opzioni

- High oil temperature shut down

- Low fuel level shut down

- Low fuel level alarm

- High fuel level alarm

Standard

- Electrical Safety / Electro Magnetic Compatibility (EMC)

- BS EN 61000-6-2 EMC Generic Immunity Standard

- BS EN 61000-6-4 EMC Generic Emission Standard

- BS EN 60950 Electrical Safety

Carica Batterie Statico

- Battery charger is manufactured with switching-mode and SMD technology and it has high efficiency.

- Battery charger models' output V-I characteristic is very close to square

- 2405 has fully output shot circuit protection and it can be used as a current source.

- 2405 charger has high efficiency, long life, low failure rate, light-weight and low heat radiated in accordance

with linear alternatives.

- The charger is fitted with a protection diode across the output.

- Charge fail output is available.

- Connect charge fail relay coil between positive output and CF output.

- Input: 196-264V.

- Output: 27,6V 5A or 13,8V 5A.

Cabina: AK 91
1. Steel structure made from steel sheet and steel profiles. 
2. canopy and panels made from powder coated sheet steel. 
3. Emergency stop push button. 
4. Control panel is mounted on the baseframe . Located at the right side of the generator set. 
5. Cables out locations are under or back of the canopy. 
6. Corrosion.resistant locks and hinges. 
7. oil could be drained via valve and a hose 
8. Exhaust system in the canopy. 
9. special large access doors (marine type) for easy maintanance 
10. Fuel tank is at front of the canopy ,easy access to the fuel tank via lockable door. 
11. Lifting points similar to ISO container , located on each top corner of the canopy. 
12. the cap on the canopy provides easy accsess to radiator cap. 
13. sound proofing materials 
14. Integrated ladder built in to side of the canopy allows access to the top of the canopy.
introduzione
Sound-attenuated and weather protective enclosures for generating sets from Aksa, meet event the sound requirements and provide optimum protection from inclement weather and development by our specialist acoustic engineers. Our modular designed sound insulated canopies provide ease of access for servicing and general maintenance and interchangeable components permitting on-site repair. Enclosures are designed to optimize genset cooling performance, providing you with confidence that genset ratings and ambient capability.
Specifiche Standard
Compact footprint, low profile design. 
Enclosure, generator set, exhaust system and fuel tank are pre-ssembled, pre-integrated and shipped as one package 
Body made from steel components treated with polyester powder coating 
Fire retardant foam insulation 
Easy access to all service points 
Exhaust system inside canopy 
Large doors on each side 
Control panel viewing window in a lockable access door 
Emergency stop push button mounted on enclosure exterior 
Cooling fan and battery charging alternator fully guarded 
Fuel fill and battery can only be reached via lockable access doors. 
Lifting points on the top of canopy and base frame 
Customer options available to meet your applications needs. 
Aksa makes its generating sets' noise level tests in accordance with directive 2000/14/EC validation of the noise level test has been aproved by the notified body Szutest

Modello Cabina AK 91
Larghezza (mm) mm. 2286
Lunghezza (mm) mm. 5920
Altezza (mm) mm. 2340
Capacità Serbatoio (L) Lt. 1100