APG 500

Product: PSI Alternator: ECO 40-3S/4 C CONTROL SYSTEM: DSE 7320
INTRODUCTION

Aksa power generation system, providing optimum performance, and reliability, for stationary standby, prime power, and continuous duty applications. All generator sets are factory build, and production tested.

General Characteristics
Model Name APG 500
Frequency (Hz) 50
Fuel Type Natural Gas
Engine Made and Model PSI - 21.9L_ APG500
Alternator Made and Model Mecc Alte - ECO 40-3S/4 C
Control Panel Model DSE 7320
Canopy AUL7A
3 Phase, 50 Hz, PF 0.8
VOLTAGE STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper
kVA kW kVA kW
400/231 500 400.00 - - 721.71
STANDBY RATING (ESP) : Applicable for supplying power to varying electrical load for the duration of power interruption of a reliable utility source. ESP is in accordance with ISO 8528-1. Overload is not allowed.

PRIME RATING (PRP) : Applicable for supplying power to varying electrical load for unlimited hours. PRP is in accordance with ISO 8528-1. 10 % overload capability is available for a period of 1 hour within 12-hour perod of operation.
ENGINE SPECIFICATIONS
Engine PSI
Engine Model 21.9L_ APG500
NO. OF CYLINDERS AND BUILD 12 cylinders - V type
BORE AND STROKE mm 128 (5) X 142 (5,6)
TOTAL DISPLACEMENT L 21,9 (1336)
Aspiration Turbo Charged
COMPRESSION RATIO 10,5:1
RATED SPEED (RPM) d/dk 1500
OIL CAPACITY L 40 (10,6)
Standby Power (kW/HP) 397 (532)
Prime Power 337 (453)
Block Heater QTY
1
Block Heater Power (Watt)
3000
Fuel Type
Natural Gas
Injection Type and System
Spark-Ignited
Type of Fuel Pump
-
Governor System
ECU
Operating Voltage (Vdc)
24 Vdc
Battery and Capacity (Qty/Ah)
2 / 120
Charge Alternator (A)
45
Cooling Method
Water Cooled
Cooling Fan Air Flow (m3/min)
971
Coolant Capacity (engine only) (l)
44 (12)
Air Filter
Dry Type
Fuel Cons. Prime With %100 Load (m3/hr)
99 (71)
ALTERNATOR SPECIFICATIONS
Manufacturer Mecc Alte
Alternator Made and Model ECO 40-3S/4 C
Frequency (Hz) Hz 50
Power (kVA) kVA 500
DESIGN   4 Pole,  Brushless
VOLTAGE V 400
Phase 3
A.V.R. DER1
Voltage Regulation (+/-) 0.5
Insulation System H
Protection IP23
Rated Power Factor 0.8
WEIGHT COMP. GENERATOR (Kg) 1534
COOLING AIR (m³/min) m3 54
SIZE and WEIGHT
Open Type DRY WEIGHT (kg.)
(kg.)
LENGTH
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
CANOPY DRY WEIGHT (kg.)
(kg.)
LENGTH
(mm.)
WIDTH
(mm.)
HEIGHT
(mm.)
TANK CAPACITY (lt.) (Lt.)
AUL7A
5200 (205) 2100 (83) 2420 (95)
STANDARD SPECIFICATIONS

- Water cooled, gas engine

- Radiator with mechanical fan

- Protective grille for rotating and hot parts

- Electric starter and charge alternator

- Starting battery (with lead acid) including rack and cables

- Engine coolant heater

- Base frame design incorporates an anti-vibration isolators

- Flexible fuel connection hoses

- Single bearing, class H alternator

- Industrial exhaust silencer and steel bellows supplied separately(for open sets)

- Static battery charger

- Manual for application and installation

CONTROL SYSTEM: DSE 7320
1. Menu navigation buttons 
2. Close mains button 
3. Main Status and instrumentation display 
4. Alarm LED's 
5. Close generator button 
6. Status LED's 
7. Operation selecting buttons
1. Menu navigation buttons 
2. Close mains button 
3. Main Status and instrumentation display 
4. Alarm LED's 
5. Close generator button 
6. Status LED's 
7. Operation selecting buttons
Devices

DSE model 7320, Auto Mains Failure control module, with a highly sophisticated level of new features and functions

Static battery charger, Fuses for control circuits

CONSTRUCTION and FINISH

- Components installed in sheet steel enclosure.

- Phosphate chemical, pre-coating of steel provides corrosion resistant surface

- Polyester composite powder topcoat forms high gloss and extremely durable finish

- Lockable hinged panel door provides for easy component access

INSTALLATION

The Control panel is mounted at the generating set baseframe on robust steel stand or power module. Located at side

of generating set with properly panel visibility.

GENERATING SET CONTROL UNIT

- The DSE 7320 control module is a standard addition to our generator sets from 220 kVA upwards and it has been

designed to start and stop diesel and gas generating sets that include electronic and non electronic engines.

- The DSE 7320 includes the additional capability of being able to monitor a mains (utility) supply and is therefore suitable

for controlling a standby generating set in conjunction with an automatic transfer switch.

- The DSE7320 also indicates operational status and fault conditions, automatically shutting down the generating set and

indicating faults by means of its LCD display on the front panel.


Instruments
ENGINE
Engine speed
Oil pressure
Coolant temperature
Run time Battery volts
Engine maintenance due

GENERATOR
Voltage (L-L, L-N)
Current (L1-L2-L3)
Frequency
Earth current
kW
Pf
kVAr
kWh, kVAh, kVArh
Phase sequence

MAINS
Voltage (L-L, L-N)
Frequency

Options

- High oil temperature shut down

- Low fuel level shut down

- Low fuel level alarm

- High fuel level alarm

Standards

- Electrical Safety / Electro Magnetic Compatibility (EMC)

- BS EN 61000-6-2 EMC Generic Immunity Standard

- BS EN 61000-6-4 EMC Generic Emission Standard

- BS EN 60950 Electrical Safety

STATIC BATTERY CHARGER

- Battery charger is manufactured with switching-mode and SMD technology and it has high efficiency.

- Battery charger models' output V-I characteristic is very close to square

- 2405 has fully output shot circuit protection and it can be used as a current source.

- 2405 charger has high efficiency, long life, low failure rate, light-weight and low heat radiated in accordance

with linear alternatives.

- The charger is fitted with a protection diode across the output.

- Charge fail output is available.

- Connect charge fail relay coil between positive output and CF output.

- Input: 196-264V.

- Output: 27,6V 5A or 13,8V 5A.

Canopy: AUL7A
STANDARD SPECIFICATIONS


CANOPY MODEL AUL7A
WIDTH mm. 2100 (83)
LENGTH mm. 5200 (205)
HEIGHT mm. 2420 (95)
TANK CAPACITY (lt.) Lt.